Lightweight Mullite Insulating Firebricks

* Illustrative image for reference only. Actual product appearance and specifications may vary by manufacturer. Learn more

Refractory Bricks Kiln & Furnace Insulation

Lightweight Mullite Insulating Firebricks

Lightweight mullite insulating firebricks from Chinese manufacturers: bulk density 0.6–1.2 g/cm³, classification temperatures 1300–1600°C, low thermal conductivity backup insulation for kilns and furnaces.

Mineralogy:
Mullite (3Al2O3·2SiO2), foamed/porous structure
Bulk Density:
≈ 0.6 – 1.2 g/cm³ (grade dependent)
Classification Temperature:
1300 – 1600°C series
Reference Price: USD 230.00–1000.00 / ton

Indicative wholesale range compiled from mainstream B2B platforms. Not a final selling price — actual quotes depend on quantity, material specs, and OEM customization.

Price Note: JM23 standard grades in volume at the low end; JM28-JM30 high-temperature grades or custom-shaped bricks in small lots at the high end.
Updated: 2026-10-19 How we compile data →

Product Overview

Lightweight mullite insulating firebrick does the job dense bricks cannot: holding the heat in. A porous, mullite-based body at 0.6–1.2 g/cm³ bulk density gives thermal conductivity far below that of dense firebrick, cutting shell temperatures and fuel consumption as backup insulation behind working linings in kilns, furnaces and kiln cars. The trade-off is mechanical strength — cold crushing strength of roughly 1.5–6 MPa means these bricks must not carry structural loads, abrasion or direct flame impingement. Grades are sold by classification temperature (typically 1300–1600°C series), and a standard safety margin of about 100–150°C between service temperature and classification temperature is common practice. Manufacturers listed here machine standard straights, arch and wedge shapes, and supply graded density systems so the hot face, intermediate layer and cold face each use the lowest-density brick the position allows.

Classification-temperature margin documentation is the insulation-design rule: the standard safety margin between service and classification temperature prevents shrinkage failures, and buyers should specify thermal-conductivity curves per lot to model shell temperatures honestly across graded-density layer systems.

Shrinkage-test data per lot further validates classification claims before hot-face installation begins.## OEM & Customization Capabilities

  • Layered Insulation Design – multi-density packages matching temperature gradient to brick grade.
  • Shaped Insulation – arch, dome and door shapes machined to drawing.
  • Property Reports – thermal conductivity curves, density and CCS per lot on request.

Industry Applications

  • Refractory Bricks
  • Kiln & Furnace Insulation

Technical Specifications

MineralogyMullite (3Al2O3·2SiO2), foamed/porous structure
Bulk Density≈ 0.6 – 1.2 g/cm³ (grade dependent)
Classification Temperature1300 – 1600°C series
Thermal ConductivityLow, rising with temperature; check hot-face rating vs working temperature
Cold Crushing Strength≈ 1.5 – 6 MPa (density dependent)
ApplicationBackup insulation behind working linings, kiln cars, furnace doors
Size Standard230x114x65mm standard straights
Site WorkEasily cut with hand saw on site
Hot Face NoteNot for direct flame contact beyond classification temperature